Plunger-in-Barrel Syringes Each plunger individually fitted for each syringe | |
|
| SPECIFICATIONS | Accuracy and Reproducibility | ± 1% | |||
| Borosilicate glass barrel OD | 6.5 mm | ||||
| 8 mm for Guided Plunger Syringes | |||||
| Scale Length | 60 mm | ||||
Fixed Needle
| Part no. | Description | Volume | Needle Length (mm) |
Needle Gauge |
OD mm | Tip Style | Syringe Code | |
|---|---|---|---|---|---|---|---|---|
| 001000 | Fixed Needle - Plunger Protection Syringes | 5µL | 50 | 26 | 0.47 | Bevel | 5F | ![]() |
| 001002 | Fixed Needle - Plunger Protection Syringes | 5µL | 70 | 26 | 0.47 | Bevel | 5F-7 | ![]() |
| 001100 | Fixed Needle - Superflex Flexible Plunger | 5µL | 50 | 26 | 0.47 | Bevel | 5FX | ![]() |
| 001105 | Fixed Needle - Superflex Flexible Plunger | 5µL | 50 | 26 | 0.47 | Cone | 5FX-5C | ![]() |
| 001839 | Fixed Needle - Plunger Protection Syringes | 5µL | 42 | 23 | 0.63 | Cone | 5F-4.2/0.63C | ![]() |
Fixed Needle - Guided Plunger
|
| Part no. | Description | Volume | Needle Length (mm) |
Needle Gauge |
OD mm | Tip Style | Syringe Code | |
|---|---|---|---|---|---|---|---|---|
| 001400 | Fixed Needle - Guided Plunger | 5µL | 50 | 26 | 0.47 | Bevel | 5F-GP | ![]() |
Removable Needle
|
| Part no. | Description | Volume | Needle Length (mm) |
Needle Gauge |
OD mm | Tip Style | Syringe Code | Replacement Needle Part no. |
|
|---|---|---|---|---|---|---|---|---|---|
| 001050 | Removable Needle - Plunger Protection | 5µL | 50 | 26 | 0.47 | Bevel | 5R | 036110 | ![]() |
| 001150 | Removable Needle - Suplerflex Flexible Plunger | 5µL | 50 | 26 | 0.47 | Bevel | 5RX | 036110 | ![]() |
Removable Needle - Guided Plunger
|
| Part no. | Description | Volume | Needle Length (mm) |
Needle Gauge |
OD mm | Tip Style | Syringe Code | Replacement Needle Part no. |
|
|---|---|---|---|---|---|---|---|---|---|
| 001450 | Removable Needle - Guide Plunger | 5µL | 50 | 26 | 0.47 | Bevel | 5R-GP | 036110 | ![]() |
| 001455 | Removable Needle - Guide Plunger | 5µL | 70 | 26 | 0.47 | Bevel | 5R-GP-7 | 036130 | ![]() |
| 001495 | Removable Needle - Short (Half Scale) Guided Plunger | 5µL | 50 | 26 | 0.47 | Bevel | 5R-GPS | 036110 | ![]() |
| 6.5mm OD barrel with Repeating Adaptor |
|
| Part no. | Description | Volume | Needle Length (mm) |
Needle Gauge |
OD mm | Tip Style | Syringe Code | Replacement Needle Part no. |
|
|---|---|---|---|---|---|---|---|---|---|
| 001090 | Removable Needle - 6.5mm OD Barrel with Repeating Adaptor | 5µL | 50 | 26 | 0.47 | Bevel | 5R-RA6 | 036110 | ![]() |
| 8mm OD barrel with Repeating Adaptor |
| Part no. | Description | Volume | Needle Length (mm) |
Needle Gauge |
OD mm | Tip Style | Syringe Code | Replacement Needle Part no. |
|
|---|---|---|---|---|---|---|---|---|---|
| 001490 | Removable Needle - Guided Plunger & Repeating Adaptor | 5µL | 50 | 26 | 0.47 | Bevel | 5R-GP-RA8 | 036110 | ![]() |
Replacement Needles For 5µl Removable Needle Syringes
Part no.
Needle Length (mm)
Gauge
OD (mm)
ID (mm)
Tip Style
Pack Size
036010 50
26
0.47
0.11
Cone
2

036011 50
23
0.63
0.11
Cone
2

036030 70
26
0.47
0.11
Cone
2

036031 70
23
0.63
0.11
Cone
2

036060 115
26
0.47
0.11
Cone
2

036110 50
26
0.47
0.11
Bevel
5

036130 70
26
0.47
0.11
Bevel
5

036160 115
26
0.47
0.11
Bevel
5

036250 51(2)
22
0.028
0.17
LC
5

036310 50
26
0.47
0.11
Sheathed/Bevel
2

036410 50
26
0.47
0.11
Side Hole/Dome
2

036510 50
26
0.47
0.11
Dome
2

036530 70
26
0.47
0.11
Dome
2

036603 50
0.17
0.10
On-column
2

036605 75
0.17
0.10
On-column
2

036610 100
0.17
0.10
On-column
2

036625 110
0.17
0.10
On-column
2

036635 100
0.17
0.10
On-column
2

036651 107
0.19
0.10
On-column
2

036675 75
0.23
0.10
On-column
2

036685 95
0.27
0.11
On-column
2