Thermo Scientific

Autosampler Syringes - AS200, AS800, AS2000, AS3000, Triplus

Thermo Scientifc GC Autosampler Syringes Fixed Needle

 

Part no. Volume Needle
Length
(mm)
Needle
Gauge
OD
mm
Tip
Style
Syringe Code Replacement
Plunger
Part no.
TriPlus AS3000 AS2000 AS200/800
0011055µL 50 26 0.47 Cone 5FX-5C *
00298910µL 80 23 0.63 Cone 10F-C/F-8/0.63C * *
00299210µL 80 26 0.47 Cone 10F-C/F-8/0.47C * *
01905010µL 50 25 0.50 Cone 10F-C/F-5/0.50C * * * *
00298710µL gas tight 50 23 0.63 Cone 10F-C/F-GT-5/0.63C 0318120 * *
00298110µL 50 23 0.63 Cone 10F-C/F-5/0.63C * * * *
00298010µL 50 26 0.47 Cone 10F-C/F-5/0.47C * * * *
00298610µL 50 26 0.47 Cone 10F-C/F-5/0.47C 6 pack * * * *

Thermo Scientifc GC Autosampler Syringes Removable Needle

 

Part no. Volume Needle
Length
(mm)
Needle
Gauge
OD
mm
Tip
Style
Syringe Code Replacement
Needle
Part no.
TriPlus AS3000 AS2000 AS200/800
0004900.5µL 50 26 0.47 Cone 0.5BNR-C/F-5/0.47C 033770 * *
0004920.5µL 50 23 0.63 Cone 0.5BNR-C/F-5/0.63C 033772 * *
00298210µL 50 26 0.47 Cone 10R-C/F-5/0.47C 037785 * * *
00298410µL 50 23 0.63 Cone 10R-C/F-5/0.63C 037787 * * * *
00299310µL 80 26 0.47 Cone 10R-C/F-8/0.47C 031535 * * * *


Liners

top

Trace and Focus GC Liners

Part no. Description OD (mm) ID (mm) Length (mm) Pack Size
092142
Trace 2000 PTV Liner
2.75 1.75 120 5
092045
Splitless FocusLiner (for use with 70mm Needle)
8 5 105 5
092155
Sintered Glass, Large Volume Injection (LVI) Liner
2.75 0.78/1.8 120 5
092141
Splitless with Single Taper
8 3 105 5
092150
Split, Straight-through Liner
8 5 105 5
092049
Splitless FocusLiner (for use with 50mm Needle)
8 5 105 5
092148
SPME Liner
8 0.8 105 5
092048
Split FocusLiner (for use with 50mm Needle)
8 5 105 5
092147
Splitless, Straight-through Liner
8 3 105 5
092144
Splitless with Single Taper
8 5 105 5
092046
Splitless FocusLiner with Top-end Restriction (for use with 70mm Needle)
8 5 105 5
09204625
Splitless FocusLiner with Top-end Restriction (for use with 70mm Needle)
8 5 105 25

For inlet liners to suit Finnigan 9001 and GCQ GCs, see the Agilent Liners page.
Dimensions of inlet liners for these GCs are the same as for Agilent GCs.

Mega 4000, 5000, and 6000 Liners

Part no. Description OD (mm) ID (mm) Length (mm) Pack Size
092041
Split / Splitless, Recessed Gooseneck with Quartz Wool
5 3 79.5 5
092047
Splitless, Straight-through Liner
5 2 79.5 5
092044
Split, Straight-through Liner
5 3 79.5 5

Liner Sealing Ring

Part no. Description Pack Size
0726004Graphite Sealing Ring - 8mm ID, For 8000 & TRACE GCs10


Septa

top

Part no. Model Diameter (mm) Septum Type Pack Size
04184918000 Series, TRACE GC 17 TCS 50
0418868000 Series, TRACE GC 17 Auto-Sep T™ 25


Ferrules

top

All ferrules are supplied in packets of 10.

Detector / Injectors
(Not for GC/MS, NOT suitable for 8000 Series and Trace/Focus GC)
 

 

072619

Part no. Column Size Material
07265490.10-0.25mm ID columns 15% Graphite/ 85% Vespel®
0726190.10-0.25mm ID columns 100% Graphite
07265570.32mm ID columns 15% Graphite/ 85% Vespel®
0726190.32mm ID columns 100% Graphite
07265480.45-0.53mm ID columns 15% Graphite/ 85% Vespel®
0726140.45-0.53mm ID columns 100% Graphite
0726691/8" OD packed columns 15% Graphite/ 85% Vespel®
0726221/8" OD packed columns 100% Graphite
0726671/4" OD packed columns 15% Graphite/ 85% Vespel®
0726211/4" OD packed columns 100% Graphite

 

For Trace Dectector/Injectors at atmospheric pressure 
 

072696

Part no. Column Size Material
0726960.10-0.25mm ID columns 15% Graphite/ 85% Vespel®*
0726970.32mm ID columns 15% Graphite/ 85% Vespel®*
0726980.53mm ID columns 15% Graphite/ 85% Vespel®*
1034085 Brass Nut for Trace GC injectors and Non-MS Detectors (packet of 2)

*These ferrules must be used in combination with brass nut (Part No. 1034085)

 

GC/MS Interface Connections  
 

072663

Part no. Column Size Description
0734500.10-0.25mm ID columns SilTite Metal - Initial Installation (10 ferrules, 2 nuts)
0733300.10-0.25mm ID columns SilTite Ferrules
0726630.10-0.25mm ID columns 15% Graphite/ 85% Vespel® Ferrules
0734510.32mm ID columns SilTite Metal - Initial Installation (10 ferrules, 2 nuts)
0733310.32mm ID columns SilTite Ferrules
0726540.32mm ID columns 15% Graphite/ 85% Vespel® Ferrules
0734520.45-0.53mm ID columns SilTite Metal - Initial Installation (10 ferrules, 2 nuts)
0733320.45-0.53mm ID columns SilTite Ferrules
0726550.45-0.53mm ID columns 15% Graphite/ 85% Vespel® Ferrules
073230 SilTite Metal Nuts (packet of 5)

 

Packed to Capillary Conversion Nut and Ferrule Kit for Thermo Finnigan Instruments/Fisons 8000 Series GC

Part no. Description Material
103436Includes a range of ferrules for
0.10 - 0.53mm ID columns
15% Graphite/ 85% Vespel®


Electron Multipliers

top

Part no. Instrument Analyzer Type Technique
14138Bench-top Traps (pre-GCQ) Ion Trap GC-MS