GC Gas Purifiers

Performance Characteristics of SGE Purifiers

Moisture Purifiers
Under laboratory temperatures and flows normally associated with GC carrier gases ie. less than 1L/min, these purifiers can be expected to reduce the moisture in a high purity gas stream to less than 10ppb and under these conditions are expected to absorb about 12g of H2O.

Hydrocarbon Traps
The capacity depends on the overall molecular weight of the contamination. Typically at 1L/min, C4 hydrocarbons should be less than 15ppb.

Oxygen Scrubbers
At flows of 1L/min, or less, of high purity gas (hydrogen, helium, and nitrogen) at laboratory temperatures, these scrubbers are expected to produce carrier gas containing less than 15ppb of oxygen. They can also remove small amounts of water without affecting the oxygen capacity. When used in conjunction with an indicating oxygen trap (GF-IOT), the oxygen content at the GC can be as low as 2ppb.

Which Purifier?
As a minimum requirement for capillary gas chromatography, especially for a new GC, SGE recommends the kit connected as shown, consisting of four gas purifiers to remove moisture, contaminating organic substances and oxygen. 

The stainless steel bodies are approximately 300mm long and 23mm OD.  They are designed for use at ambient temperature, and at pressures below 100psi.

 

Gas Purifier Kit

contains:
High Capacity Moisture trap
High Capacity Hydrocarbon Trap
High Capacity Oxygen Trap
Back-up Indicating Oxygen Trap

Part no. Description
103494 Gas Purifier Kit

Gas Purifier Selection 

1 Removes Moisture
Part no. Description Fitting
Size
Code
103480 Moisture Trap 1/4" GF-MS
103487 Moisture Trap 1/8" GF-MS

The Moisture trap can be used on all Air, Helium, Hydrogen and Nitrogen carrier gas lines. It has an impervious outer stainless steel casing and with gas flows of 1mL/min the trap can remove moisture down to 10ppb.


2 Removes Organics
Part no. Description Fitting
Size
Code
103481 Hydrocarbon Trap 1/4" GF-MSX
103488 Hydrocarbon Trap 1/8" GF-MSX

The Hydrocarbon trap absorbs hydrocarbon contaminants in the carrier gas. It has an impervious outer stainless steel casing and can remove hydrocarbons to acheive a level as low as 15ppb.


3 Removes Oxygen
Part no. Description Fitting
Size
Code
103482 Oxygen Trap 1/4" GF-O
103486 Oxygen Trap 1/8" GF-O

The Oxygen trap can remove oxygen to acheive a level as low as 15ppb. The trap has an outer stainless steel casing.


4 Indicating Oxygen Trap
Part no. Description Fitting
Size
Code
103491 Indicating Oxygen Trap 1/8" GF-IOT

The Oxygen Indicating trap is used in conjunction with the oxygen trap, indicating when it needs to be changed.


 

 

For use with Packed GC Columns - Refillable Gas Purifiers

Removes Moisture
Part no. Description Fitting
Size
Code
103495 Indicating Molecular Sieve - purifier 1/8" GF-IMS

Transparent outer casing (approximately 32mm OD x 280mm long) allows lifetime to be gauged from indicator.  (Not recommended for high resolution capillary chromatography)