GC Capillary Column Splitters

  

 

The MS/FID Splitter kit is no longer manufactured, the following spare parts are available.

  • Not suitable for use with 0.1mm ID columns
  • 1:1 split ratio 

 

 

Part no. Description
073220 Replacement SilTite metal ferrules - 0.4mm ID (packet of 10)
073221 Replacement SilTite metal ferrules - 0.5mm ID (packet of 10)
073222 Replacement SilTite metal ferrules - 0.8mm ID (packet of 10)
073224 Replacement SilTite nuts (packet of 5)
123711 Replacement restrictors - Set A for use with 0.25mm ID columns
123712 Replacement restrictors - Set B for use with 0.32mm and 0.53mm ID columns

 

 

Fixed Outlet Splitter for Capillary Columns

 


The Fixed Outlet Splitter is recommended for splitting the flow from a capillary column between two detectors. The kit consists of a special Glass Lined Tubing (GLT™) splitter union, tubing and all ferrules required for installation.

 

 

Splitter and Tubing for 0.1 - 0.32mm ID columns

Part no. Description Split
Ratio
123630 Fixed Outlet Capillary Column Splitter User Determined
1861460 Fixed Outlet Capillary Column Splitter 1:1 fixed
1861461 Fixed Outlet Capillary Column Splitter 1:5 fixed
1861462 Fixed Outlet Capillary Column Splitter 1:10 fixed

 

Replacement Tubing 

Part no. Description Split
Ratio
Pack
Size
18614600 Replacement Tubing 1:1 2
18614610 Replacement Tubing 1:5 2
18614620 Replacement Tubing 1:10 2

 

Replacement 2-hole ferrules

Part no. Description Column
ID (mm)
Pack
Size
072662 Replacement 2 hole ferrules 0.1-0.25mm 10
072664 Replacement 2 hole ferrules 0.32mm 10

 

 

 

Fixed Inlet Splitter for Capillary Columns

  • For columns from 0.10mm to 0.53mm ID
  • Ideal for confirmation retention data
  • Small internal volumes
  • Inert flow path of Glass Lined Tubing (GLT™) and fused silica

 

 

Where an injected sample is to be split between two capillary columns for simultaneous analysis, the fixed inlet splitter is recommended. The low internal volume, glass lined design ensures an inert low dead volume connection. The two capillary columns used (usually differing in polarity) must have the same length and inside diameter to obtain equal sample splitting. Three kits are available to suit 0.1-0.25mm, 0.32mm and 0.45-0.53mm ID capillary columns. The kit consists of a special GLT™ union and all ferrules required for installation.



Inlet Splitter for 0.45 - 0.53mm ID columns


 
Inlet Splitter for 0.1 - 0.25mm ID
and 0.32mm ID columns

Part no. Description Column
ID (mm)
123632 Fixed Inlet Capillary Column Splitter 0.1-0.25mm
123633 Fixed Inlet Capillary Column Splitter 0.32mm
123634 Fixed Inlet Capillary Column Splitter 0.45-0.53mm

 

 

Variable Outlet Splitter for Capillary Columns

 

 

This easy-to-install splitter allows regulation of flow to a second detector. A make-up gas tee piece is built into the valve, increasing flow velocity, eliminating potential dead volume problems and allowing detector sensitivity to be maintained. The valve adjustment control is conveniently located outside the gas chromatograph while all components in contact with the sample remain in the oven.

 

 

Part no. Description
1236291 Capillary Outlet Splitter System

• EASY • RELIABLE • LEAK FREE • NO TOOLS

FingerTite in GC oven

 

 

 

SilTite™ FingerTite is the next generation ferrule system for gas chromatography systems delivering an easy, leak free installation for capillary columns without the use of any tools.