GC Gas Purifiers

Performance Characteristics of SGE Purifiers

Moisture Purifiers
Under laboratory temperatures and flows normally associated with GC carrier gases ie. less than 1L/min, these purifiers can be expected to reduce the moisture in a high purity gas stream to less than 10ppb and under these conditions are expected to absorb about 12g of H2O.

Hydrocarbon Traps
The capacity depends on the overall molecular weight of the contamination. Typically at 1L/min, C4 hydrocarbons should be less than 15ppb.

Oxygen Scrubbers
At flows of 1L/min, or less, of high purity gas (hydrogen, helium, and nitrogen) at laboratory temperatures, these scrubbers are expected to produce carrier gas containing less than 15ppb of oxygen. They can also remove small amounts of water without affecting the oxygen capacity. When used in conjunction with an indicating oxygen trap (GF-IOT), the oxygen content at the GC can be as low as 2ppb.

Which Purifier?
As a minimum requirement for capillary gas chromatography, especially for a new GC, SGE recommends the kit connected as shown, consisting of four gas purifiers to remove moisture, contaminating organic substances and oxygen. 

Gas Purifier Kit contains:
High Capacity Moisture trap
High Capacity Hydrocarbon Trap
High Capacity Oxygen Trap
Back-up Indicating Oxygen Trap

Part no. Description
103494Gas Purifier Kit

Gas Purifier Selection 

1Removes Moisture
Part no. Description Fitting Size Code
103487Moisture Trap1/8" GF-MS
103480Moisture Trap1/4" GF-MS

The Moisture trap can be used on all Air, Helium, Hydrogen and Nitrogen carrier gas lines. It has an impervious outer stainless steel casing and with gas flows of 1mL/min the trap can remove moisture down to 10ppb.


2Removes Organics
Part no. Description Fitting Size Code
103488Hydrocarbon Trap1/8" GF-MSX
103481Hydrocarbon Trap1/4" GF-MSX

The Hydrocarbon trap absorbs hydrocarbon contaminants in the carrier gas. It has an impervious outer stainless steel casing and can remove hydrocarbons to acheive a level as low as 15ppb.


3Removes Oxygen
Part no. Description Fitting Size Code
103486Oxygen Trap1/8" GF-O
103482Oxygen Trap1/4" GF-O

The Oxygen trap can remove oxygen to acheive a level as low as 15ppb. The trap has an outer stainless steel casing.


4Indicating Oxygen Trap
Part no. Description Fitting Size Code
103491Indicating Oxygen Trap1/8" GF-IOT

The Oxygen Indicating trap is used in conjunction with the oygen trap, indicating when it needs to be changed.


Packed GC Column - Use Refillable Gas Purifiers

Removes Moisture
Part no. Description Code
103495Indicating Molecular Sieve - purifierGF-IMS
1034950Indicating Molecular Sieve - refill kit 250ccGF-IMS

Transparent outer casing allows lifetime to be gauged from indicator.


Removes Organics
Part no. Description Code
103485Activated Charcoal - purifierGF-C100
1034850Activated Charcoal - refill kit 250ccGF-C100

Ideal for non-critical applications hydrogen combustion gas lines. (Not recommended for high resolution capillary chromatography)


Publications

TitleType 
Packed Column Gas PurifiersInstruction Manual
(27 Kb)