Each plunger is individually fitted for each microsyringe for perfect sealing.
Repeating adaptors can be preset to a particular volume and help improve precision.
| SPECIFICATIONS | Accuracy and Reproducibility | ± 1% | |||
| Borosilicate glass barrel OD | 8 mm | ||||
| Scale Length | 60 mm |
| Fixed Needle |
|
| Part no. | Description | Syringe Volume | Needle Length (mm) | Gauge | OD (mm) | Tip Style | Syringe Code | |
|---|---|---|---|---|---|---|---|---|
| 003000 | Fixed Needle - Standard Plunger | 25µL | 50 | 25 | 0.50 | Bevel | 25F | |
| 004000 | Fixed Needle - Standard Plunger | 50µL | 50 | 25 | 0.50 | Bevel | 50F | |
| 005000 | Fixed Needle - Standard Plunger | 100µL | 50 | 25 | 0.50 | Bevel | 100F | |
| 006000 | Fixed Needle - Standard Plunger | 250µL | 50 | 25 | 0.50 | Bevel | 250F | |
| 007000 | Fixed Needle - Standard Plunger | 500µL | 50 | 25 | 0.50 | Bevel | 500F |
| Removable Needle |
|
| Part no. | Description | Syringe Volume | Needle Length (mm) | Gauge | OD (mm) | Tip Style | Syringe Code | Replacement Needle | |
|---|---|---|---|---|---|---|---|---|---|
| 003050 | Removable Needle - Standard plunger | 25µL | 50 | 25 | 0.50 | Bevel | 25R | 038110 | |
| 004050 | Removable Needle - Standard plunger | 50µL | 50 | 25 | 0.50 | Bevel | 50R | 038110 | |
| 005050 | Removable Needle - Standard plunger | 100µL | 50 | 25 | 0.50 | Bevel | 100R | 038110 | |
| 005055 | Removable Needle - Standard plunger | 100µL | 70 | 25 | 0.50 | Bevel | 100R-7 | 038130 | |
| 006050 | Removable Needle - Standard plunger | 250µL | 50 | 25 | 0.50 | Bevel | 250R | 038110 | |
| 007050 | Removable Needle - Standard plunger | 500µL | 50 | 25 | 0.50 | Bevel | 500R | 038110 |
| Removable Needle - 8.0mm OD Barrel with Repeating Adaptor | ||
| Part no. | Description | Syringe Volume | Needle Length (mm) | Gauge | OD (mm) | Tip Style | Syringe Code | Replacement Needle | |
|---|---|---|---|---|---|---|---|---|---|
| 003090 | Removable Needle - Repeating Adaptor | 25µL | 50 | 25 | 0.50 | Bevel | 25R-RAX | 038110 | |
| 004090 | Removable Needle - Repeating Adaptor | 50µL | 50 | 25 | 0.50 | Bevel | 50R-RAX | 038110 | |
| 005090 | Removable Needle - Repeating Adaptor | 100µL | 50 | 25 | 0.50 | Bevel | 100R-RAX | 038110 | |
| 006090 | Removable Needle - Repeating Adaptor | 250µL | 50 | 25 | 0.50 | Bevel | 250R-RAX | 038110 | |
| 007090 | Removable Needle - Repeating Adaptor | 500µL | 50 | 25 | 0.50 | Bevel | 500R-RAX | 038110 |
Replacement Needles for 25-500µL Removable Needle Syringes
| Part no. | Needle Length (mm) | Gauge | OD (mm) | ID (mm) | Tip Style | Pack Size | |
|---|---|---|---|---|---|---|---|
| 038010 | 50 | 25 | 0.5 | 0.2 | Cone | 2 | |
| 038030 | 70 | 25 | 0.5 | 0.2 | Cone | 2 | |
| 038038 | 180 | 23 | 0.63 | 0.24 | Cone | 2 | |
| 038060 | 115 | 25 | 0.5 | 0.2 | Cone | 2 | |
| 038110 | 50 | 25 | 0.5 | 0.2 | Bevel | 5 | |
| 038111 | 50 | 23 | 0.63 | 0.24 | Bevel | 5 | |
| 038115 | 50 | 22 | 0.028” | 0.37 | Bevel | 2 | |
| 038130 | 70 | 25 | 0.5 | 0.2 | Bevel | 5 | |
| 038131 | 70 | 23 | 0.63 | 0.24 | Bevel | 5 | |
| 038138 | 180 | 23 | 0.63 | 0.24 | Bevel | 2 | |
| 038160 | 115 | 25 | 0.5 | 0.2 | Bevel | 5 | |
| 038161 | 115 | 23 | 0.63 | 0.24 | Bevel | 5 | |
| 038250 | 51(2”) | 22 | 0.028” | 0.37 | LC | 5 | |
| 038260 | 50 | 25 | 0.5 | 0.2 | LC | 5 | |
| 038270 | 70 | 22 | 0.028” | 0.37 | LC | 5 | |
| 038310 | 50 | 25 | 0.5 | 0.2 | Sheathed/Bevel | 2 | |
| 038410 | 50 | 25 | 0.5 | 0.2 | Side Hole/Dome | 2 | |
| 038430 | 70 | 25 | 0.5 | 0.2 | Side Hole/Dome | 2 | |
| 038460 | 115 | 25 | 0.5 | 0.2 | Side Hole/Dome | 2 | |
| 038510 | 50 | 25 | 0.5 | 0.2 | Dome | 2 | |
| 038530 | 70 | 25 | 0.5 | 0.2 | Dome | 2 | |
| 038730 | 50 | 23 | 0.63 | 0.15 | Bevel | 5 | |
| 038735 | 50 | 23 | 0.63 | 0.15 | Cone | 2 | |
| 038910 | 50 | 25 | 0.5 | 0.2 | PTFE Coated | 2 |